Iconic Diagrams\Hydraulics\Sensors
Domains: Continuous. Size: 1-D. Kind: Iconic Diagrams (Hydraulics).
This model gives the measured pressure drop between two ports (plus and min) as an output signal:
pressure = p_plus.p - p_min.p;
p_plus.phi = p_min.phi = 0;
The model has no leakage.
Ports |
Description |
p_plus p_min |
Both pressure terminals of the pressure sensor |
Causality |
|
fixed volume flow out p_plus fixed volume flow out p_min |
|
Output |
|
pressure |
Pressure drop between the two terminals (plus and min) [Pa] |