Iconic Diagrams\Hydraulics\Pumps
Domains: Continuous. Size: 1-D. Kind: Iconic Diagrams (Hydraulics).
Description
This model represents a flow source with a fixed flow and leakage. The flow is given by the parameter phi:
p.phi = phi - G*p.p;
At the output port of the flow source a parasitic volume is mounted. A parasitic volume is a tiny volume that can be added to elements to make them more easy to simulate.
Ports |
Description |
p |
|
Causality |
|
fixed volume flow out p |
|
Input |
|
phi |
Volume flow [m3/s] |
Parameters |
|
FlowSource\phi TankRes\p_nom TankRes\p_tank TankRes\Q_leak V\V V\p_initial |
Volume flow [m3/s] Nominal pressure Tank pressure [Pa] Leakage flow at nominal pressure [m3/s] Volume of oil under pressure [m3] (hidden) The starting pressure of the volume [Pa] (hidden) |