controller-pi_sp_aw_u0_tr

Navigation:  Library > Signal > Control > PID Control > Continuous >

controller-pi_sp_aw_u0_tr

Previous pageReturn to chapter overviewNext page

Library

Signal\Control\PID Control\Continuous

Use

Domains: Continuous, Discrete. Size: 1-D. Kind: Block Diagrams.

Description

This is a PI controller with setpoint weighting. The output of this controller (in s-domain) is:

PI_sp_Equation

An anti-windup scheme has been added to this controller as well as an offset for manual output at start-up. An external tracking signal must be supplied to activate the anti-windup scheme.

Interface

Inputs

Description

SP

MV

TR

Setpoint.

Measured variable or process output.

Tracking signal.

Outputs

 

output

Controller output: input for the process.

Parameters

 

K

Ti

b

Ta

output_initial

Proportional gain.

Integral time constant (Ti > 0).

Proportional setpoint weighting parameter.

Tracking time constant.

The controller output at start-up.

Initial Values

 

yes

Should be left default!

Interesting Variables

 

PB_high, PB_low

Upper and lower bound of the proportional band.