positionsensor-absolute

Navigation:  Library > Iconic Diagrams > Mechanical > Rotation > Sensors >

positionsensor-absolute

Previous pageReturn to chapter overviewNext page

Library

Iconic Diagrams\Mechanical\Rotation\Sensors

Use

Domains: Continuous. Size: 1-D. Kind: Iconic Diagrams (, Block Diagrams.), Block Diagrams.

Description

This model translates a angular position to an output signal. It has a force out causality. The equations are:

 

p.T = 0;

phi = int(p.omega);

 

Interface

Ports

Description

p_high, p_low

Rotation port p.

Causality

 

fixed force out

 

Output

 

phi

Absolute angular position [rad]

Initial Values

 

phi_initial

Initial angular position [rad]